The Standard in Rugged Power Products

Home Up Products Representation Employment News Resources Search Feedback

ETI0001-2275 2.0 kVA All of these products are manufactured by ETI in the United States.

Up
ETI0001-1202 1.5 kVA
ETI0001-1214 3.0 kVA
ETI0001-1229 2.0 kVA
ETI0001-1230 1.5 kVA
ETI0001-1230AA 1.5 kVA
ETI0001-1233 2.0 kVA
ETI0001-1233AA 2.0 kVA
ETI0001-1235 1.0 kVA
ETI0001-1237 2.0 kVA
ETI0001-1237AA 2.0 kVA
ETI0001-1240 1.0 kVA
ETI0001-1241 3.0 kVA
ETI0001-1242 1.0 kVA
ETI0001-1250 1.5 kVA
ETI0001-1251 1.5 kVA
ETI0001-1251AE 1.5 kVA
ETI0001-1252 1.5 kVA
ETI0001-1253 2.0 kVA
ETI0001-1254 2.0 kVA
ETI0001-1255 1.5 kVA
ETI0001-1285AA 1.5 kVA
ETI0001-1287AA 1.0 kVA
ETI0001-2205A3 5.0 kVA
ETI0001-2205E1 3.0 kVA
ETI0001-2205E2 3.0 kVA
ETI0001-2210 1.5 kVA
ETI0001-2214 3.0 kVA
ETI0001-2215 4.0 kVA
ETI0001-2221 2.2 kVA
ETI0001-2227 1.0 kVA
ETI0001-2227AA 1.0 kVA
ETI0001-2227AB 1.0 kVA
ETI0001-2227AC 1.0 kVA
ETI0001-2227AD 1.0 kVA
ETI0001-2227AG 1.0 kVA
ETI0001-2227E 1.0 kVA
ETI0001-2228 1.5 kVA
ETI0001-2228AA 1.5 kVA
ETI0001-2228AC 1.5 kVA
ETI0001-2228E 1.5 kVA
ETI0001-2229 2.0 kVA
ETI0001-2229AG 2.0 kVA
ETI0001-2229AM 2.0 kVA
ETI0001-2229E 2.0 kVA
ETI0001-2250 2.0 kVA
ETI0001-2250AB 2.0 kVA
ETI0001-2258 1.5 kVA
ETI0001-2275 2.0 kVA
ETI0015-2221 1.1 kVA
ETI0015-2222 2.0 kVA

Part Number: ETI0001-2275
Extreme Environment 2000 VA UPS
Fixed Mount or Rackmount

2 kVA Extreme UPS® w/ Input PFC, Manual Bypass and Self Test
Used in Extreme Temperature Environments including
Outdoor
Shelters and Switchgear Applications
Supports Computers and Harsh Inductive Loads at the Same Time
Rugged Fixed Mount or Rackmount Unit 
 

ETI0001-2275 Rugged MilSpec UPS Standard Front Panel Layout
ETI0001-2275 Rugged Mil Spec UPS Standard Front Panel Layout

ETI0001-2275 Rugged MilSpec UPS Standard Rear Panel Layout
ETI0001-2275 Rugged Mil Spec UPS Standard I/O Panel Layout

The field proven Extreme UPS® line is ideally suited for industrial, military, computer and telecommunications applications requiring high reliability, rugged construction, compact size and light weight design. These units are equally suited for use in locations with controlled or uncontrolled environments including fixed, field deployed, vehicular, shipboard or airborne.  For example, thousands of "ETI0001-2275" units are being used in the switchgear of wind turbine generators around the worldIn this application, the output supports both a computer type load and operates large inductive switchgear contactors at the same time. This places extreme demands in electrical performance that causes most other vendors' UPS products to fail. In the case of the ETI0001-2275, it is able to provide the large surge currents required to operate the contactors without dropping the voltage and loosing the computer load!! On top of this, the equipment operates in harsh temperature environment ranging from as low as -4Fahrenheit (-4Celsius) to as high as 149° Fahrenheit (65° Celsius).

The heavy-duty chassis, occupying minimal space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration.  These units can be mounted horizontally or vertically. Optional heavy-duty rack slides provide easy installation and removal of the unit with full extension.

The internal shielded input transformer provides galvanic isolation with provisions for both domestic (115 VAC, CONUS) and international (230 VAC, OCONUS) input voltages. The optional autoranging input voltage selection allows inputting either 115 VAC or 230 VAC without having to open the UPS enclosure. These units work equally well from all AC sources including poorly regulated generators. Special EMI/RFI filters and input power factor correction minimize both input current and harmonics.  The unit also operates as a frequency converter, taking 46-70 hertz input and converting it to clean, uninterruptible 60 hertz power. The input switch and the galvanic isolation transformer all provide a double pole isolated source for shipboard systems or overseas locations where phase references and grounding are not always consistent. The nominal 120 VAC, 60 hertz output can be field set for 100, 110 or 115 VAC. An alternate version is also available for 200-240 VAC, 50 hertz output. 

All controls and protective devices are brought to the outer panels with critical switches or circuit breakers having finger guards. Further, all critical devices have finger guards to prevent damage or accidental operation. The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments. The internal intelligent thermal sensors provide monitoring of unit temperatures. The optional Elapsed Time Indicator records the number of operational hours for records and scheduling preventative maintenance of attached equipment. The front panel also provides easy access to both the AC Input circuit breaker and Battery Input fuse. Coupled with the onboard spare fuse, MTTR is reduced to less than 15 minutes.

The input circuit breaker and the galvanic isolation transformer all provide a double pole isolated source for all installations including shipboard systems or overseas locations where phase references and grounding are not consistent. The manual bypass feature included is operated from the front panel. Even in the bypass mode, the ETI0001-2275 still provides galvanic isolation, transient surge protection and EMI/RFI filtering. The unit also has a self test feature that can be initiated by the operator from the front panel.

The ETI0001-2275 has the added benefit of having a field replaceable battery tray. Even with this battery tray removed, this UPS can continue to operate as an electronic power conditioner and frequency converter, providing clean, well regulated, sinusoidal power to the load. The batteries are maintenance free with immobilized electrolyte and are constructed of flame retardant materials for added safety. For more information, see the Battery Technology section. 

Removable and washable air filters and a high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. This unit draws air through the intake filters and exhausts out the rear or side vents. This allows the unit to be used in negative or neutral pressure racks. For positive pressure systems, other versions are available. The removable and washable metal screen air filters and high capacity stainless steel ball bearing fans provide added protection in both controlled and hostile environments. 

The I/O panel provides locking connectors for the input and output power. Multiple input and output power panel options are available. The exhaust air is diverted out the rear vent, with alternate air flow directions optional. See the Power Distribution Units section for a listing of stand alone PDUs. See the N5 Series section for versions of UPS with an integrated PDU and remote control. The Status connector provides an interface with optional computer software providing loss of AC and low battery status as well as remote shut down capability. 

Overall, the Extreme UPS® line is uniquely qualified for critical land based, shipboard, vehicle or airborne  systems combining advanced modular design features with highly reliable construction.

Technical Specifications:
P/N:
ETI0001-2275

AC OUTPUT
Output voltage: Nominal 120 VAC true sinewave output standard, optional 220 VAC version
Output voltage adjustment: Can be set for 100, 110, 115 or 120 VAC via DIP switches
Output rating: UPS 2000 VA, 1400 watts standard
Available in 1000, 1500, 2000 and 3000 VA ratings
Non-linear load capacity: UPS Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: UPS 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: UPS Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 Hz ± 2.5% synchronized to utility
60 Hz ± 1.0% w/ utility not available

50 Hz output available as an option
Operational status AC Input status, UPS operational, UPS alarm, Battery level, Low battery, Load level, Overload and Manual bypass LEDs, Alarm contacts for Loss of AC and Low Battery
+90 dB audible alarm with audible on/off switch
Asynchronous serial COM port, optional SNMP/HTTP and Elapsed Time Indicator
AC INPUT
Input voltage selection: Autoranging from nominal 115 VAC to 230 VAC
Input voltage tolerance: UPS +15% -25%, or 85-135 and 170-270 
@ full load without using battery, to 70 VAC @ 75% load
Input frequency: From 46 Hz to 70 Hz standard, optional to 440 Hz
Input power factor: Better than 95% typically
Input/output isolation: 2000 VA, up to 120 dB common mode, <1.0 mA leakage
Input transient suppression: Complies with IEEE 587, UL 1449 and Mil Std 1399
Input control/protection: Guarded 2 pole 100 G shock rated circuit breaker (CB1)
Manual bypass switch to force bypass mode
Optional cold start switch available to turn on w/o AC present
Input power connections: One (1) AMP CPC, 3 pin, locking
INTERNAL BATTERY
Internal Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Internal Rated for continuous service life of 5 years
Internal Front panel mounted fuse (F1), spare fuse on front
Internal battery time: 15+ minutes @ full load
30+ minutes at 50% load
Internal battery recharge: Recharged to nominal in <8 hours
Internal battery replacement: Battery module tray from top of unit
<30 minutes to change battery modules
Battery expansion: Up to 24 hours w/ optional Battery Expansion Modules
DISTRIBUTION PANEL
Output circuits: Three (3) AC outputs standard, several optional configurations
Output control: Only via CB1; optional remote control panel w/switches available
Output receptacles: AC output  Two (2) NEMA 5-15R and one (1) AMP CPC standard, various options
MECHANICAL
Dimensions (H x D x W): UPS 7.0 (4U) x 26 x 19.0 in (178 x 660 x 483 mm)
Rack Slide Mount Patterns: General Devices patterns standard, others optional
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Unit weight: UPS and Battery
                UPS only
                Battery Module only
112 lb. (51 kg) with lift handles
70 lb. (32 kg) with lift handles
42 lb. (19 kg) with lift handle
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, negative pressure, forced air
Cooling air direction: Side intake, exhaust to opposite side, others optional
Air intake filter: Washable foam or metal filter media options
ENVIRONMENTAL
Storage temperature: -40° to 158° F ambient (-40° to 70° C) with fully charged batteries with fully charged batteries
Operating temperature: 32° to 122° F ambient ( 0° to 50° C),
-40° to 149° F ambient ( -40° to 65° C) optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Storage elevation: Up to 40,000 ft (12,192 m)
Operating elevation: Up to 15,000 ft (4,572 m), higher optional
STANDARDS
United States: ETL Listed to UL-1778 standard for UPS equipment,
MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC Part 15, Class A; EN55022; optional MIL STD 461 
OPTIONAL ACCESSORIES
  Emergency Power Off, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits

This page was last modified on: April 12, 2012
The N5 is one of the most popular configurations for new programs!

  Request Information

ETI Rugged Power UPS are the proven Standard!

Home Up Products Representation Employment News Resources Search Feedback

Send questions or comments about this web site to sales@ruggedsystems.com.
Copyright © 1991-2012 Energy Technologies, Inc. All Rights Reserved. Last modified: April 10, 2012
1st Energy™, 1st Power™, 911 Power™, AC anytime™, AC anywhere™, AC backup™, Airborne UPS™, Air Force Backup™, Air Force UPS™, Army UPS™, Backup AC™, Backup Source™, Backup The Web™, Battle Power™, Blackout Prevention™, Business Back UPS™, clean UPS™, Coast Guard Power™, Coast Guard UPS™, Controlling Power™, DC backup™, Disaster Recovery Gear™, Eco Power Source™, eDocs Port™, Energy Tech™, ETI™, Expeditionary Solar™, Extreme Power Source™, Global Power Source™, Global UPS™, Homeland Security Surveillance™, Humanitarian Power™, Hybrid Energy Storage™, Improved Power™, Industrial Backup™, Intelligent PDU™,  Intelligent UPS™, Internet Power Manager™, Lab Power™, Lab UPS™, Light UPS™, Know Power™, Marine Corps Power™, Marine UPS™, Medical Grade Power™, Military Backup™, Navy Power™, Navy UPS™, Network Power Manager™, Office UPS™, open UPS™, Personal Power Source™, Petro Chem Power™, Pipeline Power™, Portable Power Plant™, Powering The Net™, Power Protection™, Power Security™, Preventing Blackouts™, Radar Power™, Railroad Power™, Redundant Power™, Renewable Source™,  Rugged Power™, Rugged Systems™, Rugged UPS™, SCADA power™, Security Gate Power™, Shipboard Power™, Shipboard UPS™, Signal Backup™, Solar Backup™, Solar Power Source™, Soldier Power™, Tactical Computers™, Tactical Medical Office™, Tactical Office™, Tactical Solar Fly™, Tactical Trailer™, Tactical Water Plant™, Telecom Power Source™, the Warfighter™, Traffic Backup™, Traffic Signal Backup™, UPStart™, Utility Backup™, and Warfighter Power™  are trademarks of Energy Technologies, Inc.

Airborne Power®, Diplomatic Power®, Expeditionary Power®, Extreme UPS®, Hybrid Energy Technologies®, Industrial Power Source®, Military Power®,  Mil Spec®, Personal Solar®, Tactical Cables®, Tactical Cooling®, Tactical Computer Workstation®, Tactical Data Vault®, Tactical Field Office®, Tactical Fuel Cells®, Tactical Generator®, Tactical Inverter®, Tactical Micro Grid®, Tactical Power®, Tactical Power Plant®, Tactical Shelter Systems®, Tactical Solar®, Tactical Solar Shelter®, Tactical UPS®, Tactical Vehicle Power®, Tactical Wind Turbine® and Ultimate Survival Gear® are registered trademarks of Energy Technologies, Inc.

Legal Statements