The Standard in Rugged Power Products

Home Up Products Representation Employment News Resources Search Feedback

ETI0001-1467 2.0 kVA All of these products are manufactured by ETI in the United States.

Up
ETI0001-1402 1.5 kVA
ETI0001-1403 1.5 kVA
ETI0001-1406 3.0 kVA
ETI0001-1417 1.5 kVA
ETI0001-1419 2.0 kVA
ETI0001-1420, 1.0 kVA
ETI0001-1429 2.4 kVA
ETI0001-1437 2.0 kVA
ETI0001-1438 2.0 kVA
ETI0001-1439 4.0 kVA
ETI0001-1442 4.0 kVA
ETI0001-1443 2.0 kVA
ETI0001-1444 2.0 kVA
ETI0001-1445 2.0 kVA
ETI0001-1447 2.0 kVA
ETI0001-1450 2.0 kVA
ETI0001-1451 4.0 kVA
ETI0001-1451AA 4.0 kVA
ETI0001-1452 4.0 kVA
ETI0001-1452AA 4.0 kVA
ETI0001-1453 4.0 kVA
ETI0001-1455 4.0 kVA
ETI0001-1456 4.0 kVA
ETI0001-1458 2.0 kVA
ETI0001-1467 2.0 kVA
ETI0001-1473 2.0 kVA
ETI0001-1473AA 2.0 kVA
ETI0001-1473AF 2.0 kVA
ETI0001-1473A 2.0 kVA
ETI0001-1473B 2.0 kVA
ETI0001-1474 2.0 kVA
ETI0001-1479 1.0 kVA
ETI0001-1482 2.0 kVA
ETI0001-1483 2.0 kVA
ETI0001-1486 2.0 kVA
ETI0001-1488 5.0 kVA
ETI0001-1488A1 5.0 kVA

Part Number: ETI0001-1467
NSN: 6130-01-544-7251
4000 VA Rugged Integrated
Rackmount UPS and Intelligent
Power Distribution Unit

US Navy IT-21, SNAP III, JMOC, ADNS, MAST, SPAWAR Standard Product
Military Power® Configuration with Ethernet 10BaseT Communications
Isolated UPS, 2000 VA Rugged Rack Mount UPS w/ Integrated
6 Circuit, 2 Pole, Intelligent, Solidstate Power Distribution Unit

ETI0001-1467 2000VA Rugged UPS Front View
ETI0001-1467 Standard Front Panel Layout

NSN: 6130-01-544-7251

ETI0001-1467 2000VA Rugged UPS Rear View
ETI0001-1467 Standard Rear Panel Layout

The field proven Military Power® UPS line is ideally suited for military, industrial and telecommunications applications requiring a rugged rack, vehicular or field deployable, high reliability, compact size and light weight design. The heavy-duty chassis occupies only 3U (5.25”) of rack space while delivering up to 2000 VA of clean, uninterruptible power. The rounded metal corners and rugged handles, both front and rear, aid in safe handling. Internally, all major components are well secured and electrically insulated to prevent damage due to shock and vibration. The internal shielded input transformer provides galvanic isolation with provisions for both domestic (CONUS) and optional autoranging international input voltages (OCONUS). The LED arrays keep the operator informed as to the unit's status including load and battery levels. The high intensity audible alarm can be heard in high noise environments, yet is easily adjustable to suit quieter conditions. All controls and protective devices are brought to the front panel with critical switches or breakers guarded. Further, all front panel devices are recessed to prevent damage or accidental operation. The internal intelligent PDU allows control of the individual output circuits incorporating thermal and interlock interfaces for additional control and safety, plus Battleshort override. The display and control panel can be mounted remotely in the rack, or on the keyboard console, or on the unit front panel with only a logic level cable connection. Both the input breaker and isolation transformer provide double pole isolation for shipboard systems.

The rear panel provides locking connectors for the input and output power with various optional configurations available. The washable air filters and high capacity ball bearing fan provide added protection in both controlled and hostile environments. The external battery connector allows the safe and easy addition of extra battery modules without having to shut the unit down. A frequency selection switch is available for those sites requiring 50-hertz output instead of the standard 60-hertz.  The status D shell connector provides signals to interface with optional computer software providing loss of AC and low battery status. The RJ45 LAN port provides an SNMP/HTTP interface for various UPS parameters.

Overall, the Rugged Power line is uniquely qualified for critical shipboard, vehicle, airborne or land based systems combining advanced modular design features with highly reliable construction.

Technical Specifications:
P/N: ETI0001-1467
NSN: 6130-01-544-7251

AC OUTPUT
Output voltage: 120 VAC true sinewave std, up to 600 VAC optional
Output rating: UPS 2000 VA in 3U chassis
0.65-0.75 pf std, optional configurations to 24,000 VA
Non-linear load capacity: Up to 100% non-linear load capability w/o derating
Output voltage regulation: UPS ± 3.0% static regulation of nominal
± 4.0% dynamic (0 to 50% load step)
Overload surge capacity: 110% for 10 minutes; 125% for 30 seconds
Harmonic distortion: Less than 5.0% into 100% non-linear load
Output frequency: UPS 60 or 50 Hz ± 2.5% synchronized to utility
60 or 50 Hz ± 1.0% w/ utility not available

400 or 1000 Hz output available as an option
Operational status Status, load and battery level LEDs, w/contacts
Adjustable level,+90 dB audible alarm w/on/off
10BaseT Ethernet SNMP/HTTP com port
AC INPUT
Input voltage selection: 120 VAC, optional up to 600 VAC, up to 440 Hz
Input voltage tolerance: UPS +15% -25% of nominal input rating
Input/output isolation: Up to 120 dB electrical noise attenuation
Input transient suppression: Complies with IEEE 587 and UL 1449
Input control/protection: Guarded 2 pole input breaker w/ UPS fuse
Optional cold start to turn on w/o AC present
Input power connection: AMP CPC Type XII locking, various options
BATTERY
Type: Maintenance free immobilized electrolyte,
Flame retardant materials (Oxygen Index 28+)
Battery life: Rated for continuous service life of 5 years
DC protection: Front panel mounted fuse, optional breaker
Battery expansion: Up to 24 hours w/ Battery Expansion Modules
DISTRIBUTION PANEL
Output circuits: Six controlled outputs w/2 pole solidstate relays
Output control: Local/remote control panel w/rocker switches
Thermal and remote interlock ON/OFF control
Output receptacles: (6) NEMA 5-15R w/cord restraints, various options
MECHANICAL
Dimensions ( H x D x W ): 5.25 (3U) x 23.5 x 19.0 in (133x597x483mm)
Rack Slide Mount Patterns: Jonathan, General Devices or Emcor patterns
Alternate Mounting Options: Table, Wall, Floor, Portable, Horizontal/Vertical
Shipping weight: 115 lb. (52 kg) with lift handles front and rear
Audible noise: Less than 47 dB @ 5.0 ft., ANSI "A" scale
Cooling type: High capacity, positive pressure, forced air
Cooling air direction: Rear intake, exhaust to front or sides or both
Air intake filter: Washable filter media, various porosities
ENVIRONMENTAL
Storage temperature: -13° to 131° F ambient (-25° to 55° C )
Operating temperature: 32° to 113° F ambient (0° to 45° C ),higher optional
Operating humidity: 0 to 95% relative humidity (non-condensing)
Operating elevation: Up to 15,000 ft (4,572 m), higher optionally
STANDARDS
United States: Meets UL-1778 standard for UPS equipment,
MIL STDs 810, 454 & 1399 Shock/Vib/Electrical
Canada: CSA C22.2 No. 107 UPS safety requirements
EMI Protection: EMI/RFI FCC, Class A, optional MIL STDs 461
OPTIONAL ACCESSORIES
  Dual Source Input, Batteryless Operation,
Battery Expansion Unit, Automatic Battery Test, Software Interface

This page was last modified on: March 18, 2012
The N5 is one of the most popular configurations for new programs!

  Request Information

The N5 is one of the most popular configurations for new programs!

Home Up Products Representation Employment News Resources Search Feedback

Send questions or comments about this web site to sales@ruggedsystems.com.
Copyright © 1991-2012 Energy Technologies, Inc. All Rights Reserved. Last modified: April 10, 2012
1st Energy™, 1st Power™, 911 Power™, AC anytime™, AC anywhere™, AC backup™, Airborne UPS™, Air Force Backup™, Air Force UPS™, Army UPS™, Backup AC™, Backup Source™, Backup The Web™, Battle Power™, Blackout Prevention™, Business Back UPS™, clean UPS™, Coast Guard Power™, Coast Guard UPS™, Controlling Power™, DC backup™, Disaster Recovery Gear™, Eco Power Source™, eDocs Port™, Energy Tech™, ETI™, Expeditionary Solar™, Extreme Power Source™, Global Power Source™, Global UPS™, Homeland Security Surveillance™, Humanitarian Power™, Hybrid Energy Storage™, Improved Power™, Industrial Backup™, Intelligent PDU™,  Intelligent UPS™, Internet Power Manager™, Lab Power™, Lab UPS™, Light UPS™, Know Power™, Marine Corps Power™, Marine UPS™, Medical Grade Power™, Military Backup™, Navy Power™, Navy UPS™, Network Power Manager™, Office UPS™, open UPS™, Personal Power Source™, Petro Chem Power™, Pipeline Power™, Portable Power Plant™, Powering The Net™, Power Protection™, Power Security™, Preventing Blackouts™, Radar Power™, Railroad Power™, Redundant Power™, Renewable Source™,  Rugged Power™, Rugged Systems™, Rugged UPS™, SCADA power™, Security Gate Power™, Shipboard Power™, Shipboard UPS™, Signal Backup™, Solar Backup™, Solar Power Source™, Soldier Power™, Tactical Computers™, Tactical Medical Office™, Tactical Office™, Tactical Solar Fly™, Tactical Trailer™, Tactical Water Plant™, Telecom Power Source™, the Warfighter™, Traffic Backup™, Traffic Signal Backup™, UPStart™, Utility Backup™, and Warfighter Power™  are trademarks of Energy Technologies, Inc.

Airborne Power®, Diplomatic Power®, Expeditionary Power®, Extreme UPS®, Hybrid Energy Technologies®, Industrial Power Source®, Military Power®,  Mil Spec®, Personal Solar®, Tactical Cables®, Tactical Cooling®, Tactical Computer Workstation®, Tactical Data Vault®, Tactical Field Office®, Tactical Fuel Cells®, Tactical Generator®, Tactical Inverter®, Tactical Micro Grid®, Tactical Power®, Tactical Power Plant®, Tactical Shelter Systems®, Tactical Solar®, Tactical Solar Shelter®, Tactical UPS®, Tactical Vehicle Power®, Tactical Wind Turbine® and Ultimate Survival Gear® are registered trademarks of Energy Technologies, Inc.

Legal Statements