|
Part Number: ETI0001-1285AA
|
AC OUTPUT | |
Output voltage: UPS | 120 VAC true sinewave standard, up to 600 VAC optional |
Output rating: UPS | 1500 VA standard,
optional to 2400 VA in 3U 0.65-0.75 pf standard, optional configurations to 24,000 VA |
Non-linear load capacity: UPS | Up to 100% non-linear load capability w/o derating |
Output voltage regulation: UPS | ± 3.0% static regulation of nominal ± 4.0% dynamic (0 to 50% load step) |
Overload surge capacity: UPS | 110% for 10 minutes; 125% for 30 seconds |
Harmonic distortion: UPS | Less than 5.0% into 100% non-linear load |
Output frequency: UPS | 60 Hz ± 1.0% independent of input frequency 50, 400 or 1000 Hz output available as an option |
Operational status | Status, load and battery LEDs, w/contacts Adjustable level,+90 dB audible alarm w/on/off |
AC INPUT | |
Input voltage selection: | Nominal 115/230 VAC, autoranging input |
Input voltage tolerance: UPS | 86-270 VAC @ full load without using battery, to 70 VAC @ 75% load |
Input frequency: | From 45 Hz to 440 Hz standard |
Input power factor: | Better than 99% typically |
Input/output isolation: | 1500 VA, up to 120 dB common mode, <1.5 mA leakage |
Input transient suppression: | Complies with IEEE 587 and UL 1449 |
Input control/protection: | Guarded 2 pole
circuit breaker and fuse Optional cold start to turn on w/o AC present |
Input power connection: | AMP CPC 206036-2, 3 pin, threaded locking |
INTERNAL BATTERY | |
Internal battery type: | Maintenance free immobilized electrolyte, Flame retardant materials (Oxygen Index 28+) |
Internal battery life: | Rated for continuous service life of 5 years |
Internal DC protection: | Front panel mounted fuse standard, breaker optional |
Internal battery recharge: | Recharged to nominal in <8 hours |
DISTRIBUTION PANEL | |
Output circuits: | Six outputs standard, optional configurations |
Output control: | Optional remote control panel w/rocker switches |
Output receptacles: | NEMA 5-15R standard, other options |
MECHANICAL | |
Dimensions ( H x D x W ): | 5.25 (3U) x 23.5 x 19.0 in (133 x 597 x 483 mm) |
Rack Slide Mount Patterns: | Jonathan, General Devices patterns, others optional |
Alternate Mounting Options: | Table, Wall, Floor, Portable, Horizontal/Vertical |
Unit weight: UPS | 90 lb. (41 kg) UPS with lift handles front and rear |
Audible noise: | Less than 47 dB @ 5.0 ft., ANSI "A" scale |
Cooling type: | High capacity, positive pressure, forced air |
Cooling air direction: | Front intake, exhaust to rear, others optional |
Air intake filter: | Washable metal filter media, others optional |
ENVIRONMENTAL | |
Storage temperature: | -40° to 158° F ambient (-40° to 70° C) with fully charged batteries |
Operating temperature: | -4° to 131° F ambient ( -20° to 55° C), lower/ higher optional |
Operating humidity: | 0 to 95% relative humidity (non-condensing) |
Storage elevation: | Up to 40,000 ft (12,192 m) |
Operating elevation: | Up to 15,000 ft (4,572 m), higher optional |
STANDARDS | |
United States: | Meets UL-1778 standard for UPS equipment, MIL STDs 167-1, 454, 810, 901D Grade A, 1399-300A & 2000 |
Canada: | CSA C22.2 No. 107 UPS safety requirements |
EMI Protection: | EMI/RFI FCC Part 15, Class A, MIL STD 461 standard |
OPTIONAL ACCESSORIES | |
Autoranging International Input, Cold Start, Emergency Power Off, Elapsed Time Meter, Alternate I/O Configurations, Dual Source Input, Battery Expansion, Batteryless Operation, Battery Charger/Conditioner, Power Distribution Units, Software Interface, Asynchronous serial COM port, 10BaseT Ethernet SNMP/HTTP port, Transport Cases, Slides and Mounting Kits |
This page was last modified on:
April 12, 2012